Motor Protection
STR   49-50-51R-46-37-66-50N-51N
SVR 27-59-59N-27P-47-27T-59T
 
 
Transformer Protection
SSG 50-51-67-50N-51N-59N-67N
SKC 49-50-51-50N-51N-87-87N
SIG 50-51-50N-51N
SHG 50-51-50N-51N
Power Generation Protection
NTG
SKC 49-50-51-50N-51N-87-87N
SCF 25

STR - Microprocessor-based relay for motor protection 49-50-51R-46-37-66-50N-51N

Description 

The relay STR is intended for the complete protection of high power motors with medium voltage or low voltage supply. Several protection functions incorporated in a single relay assure the protection of the motor against all the different fault conditions; overheating caused by mechanical overload or by an abnormal supply, locked rotor, too long starting, interruption of one phase conductor, current unbalance, short circuit between phases, short circuit between turns, earth fault, underload running, too frequent startings.

SVR  27-59-59N-27P-47-27T-59T  Microprocessor-based relay for voltage protection

DESCRIPTION
The relay type SVR is intended for the protection of electric lines and machines against voltage variations. The following protection and monitoring functions are available, all with independent time delay:
undervoltage protection (27),
overvoltage protection (59),
residual voltage protection (59N) against earth faults (available upon request),
positive sequence undervoltage protection (27P),
negative sequence overvoltage protection (47),
dead line monitoring (27T),
live line monitoring (59T).

Svr.jpg (10532 bytes)

SSG  50-51-67-50N-51N-59N-67N
Feeder directional/non directional phase and earth overcurrent digital relay

DESCRIPTION
The relays type SSG are intended for the protection against overloads, short circuits and earth faults in radial networks, ring mains or variable structure networks.
The relay features the following characteristics:
* directional and not directional functions for both overcurrent and earth fault protections;
* phase lock loop circuit with memory of the reference voltage for the directional functions (67);
* protection functions and final relays fully programmable;
* selectable operation curves with independent or dependent time both for the overcurrent and for the earth fault functions.

scc.jpg (12031 bytes)

SIG 50-51-50N-51N Phase and earth overcurrent digital relay

DESCRIPTION
The relay type SIG is intended for the protection of electric lines and machines against overloads, short circuits and earth faults.

Svr.jpg (10532 bytes)

SHG - Microprocessor-based relay for overcurrent and earth fault protection 50-51-50N-51N

DESCRIPTION

SHG relay is intended for protection of electric lines and machines against overloads, shortcircuits and earth faults

SKC  49-50-51-50N-51N-87-87N  Microprocessor-based current differential relay with overcurrent, earth fault and thermal elements

DESCRIPTION
The differential current relays type SKC is intended for the protection of generators, large motors, two winding power transformers and short lines. The following functions are provided:
thermal (49) for transformer programmable on one of the two sides;
overload (51) and short circuit (50) independently programmable on both sides;
earth fault (50N-51N) or restricted earth fault (87N);
biased differential function for transformers with second and fifth harmonic restraint (87T);
biased differential function for motors, generators, and short lines (87G).

                                                       

     scc.jpg (12031 bytes)

NTG Generator multifunction protection relay

DESCRIPTION
The NTG digital protection relay integrates a number of functions required for the protection of generators. It is used in power stations from gas, steam, hydraulic turbine, or diesel driven generators, operating in parallel with the public grid and/or in isolation and with any neutral state and grid layout.  According to the hardware configurations BASIC and PRO, the NTG protection relay can be shipped with different sets of protection functions.

NTG performs the following protection functions:
21-51V Underimpedance or Voltage-controlled overcurrent protection
24 Overexcitation (V/Hz)
26 Thermal protection by 8 PT100 thermometric probes
27 Undervoltage
27H-59H Third harmonic Under/Overvoltage (100% stator ground)
32 Directional power
32R Reverse power
37P Underpower
40 Loss of Field
46 Negative sequence overcurrent
49 Thermal overload
50/51 Overcurrent
50+27 Switch onto standstill (InadvertentEnergizing)
50G/51G-87N Neutral overcurrent (90% stator ground in current) or, alternatively, high impedance restricted earth fault.
59 Overvoltage
59N Neutral overvoltage (90% stator ground in voltage)
64F Rotor ground
81> Over frequency
81< Under frequency
BF Breaker failure
74CT Phase CT monitoring
74VT Line VT monitoring
74TCS Trip circuit monitoring

SCF - Microprocessor-based synchronising relay 25

Description

The relay type SCF is intended for synchronising of generator units and paralleling to the network. Several functions which are necessary to carry out the paralleling are accomodated in a single relay. The design is based on a microprocessor to assure a high degree of adaptivity and ease of use.

scc.jpg (12031 bytes)

Contact Us At: sales@comlec.com BACK to Protective Relays Homepage

Have a Project and Need Options ?

Complete our Project Enquiry Form and we will quote you our best possible options that meet your specific needs.

 