Transformers
DC power supply
Voltage Stabilisers
Inductors and Harmonic Filters
Special Products

RTOX - three phase inductor for output power converters

Inductor for conditioning the output voltage of the power converter

 

Products in this family
Reference In(A) L(mH) Volt. drop
RTOX 2,5 2,5 A 8,821 3 %
RTOX 4 4 A 5,513 3 %
RTOX 5 5 A 4,411 3 %
RTOX 6,3 6,3 A 3,501 3 %
RTOX 8 8 A 2,757 3 %
RTOX 10 10 A 2,205 3 %
RTOX 12,5 12,5 A 1,764 3 %
RTOX 16 16 A 1,378 3 %
RTOX 20 20 A 1,103 3 %
RTOX 25 25 A 0,882 3 %
RTOX 31,5 31,5 A 0,700 3 %
RTOX 40 40 A 0,551 3 %
RTOX 50 50 A 0,441 3 %
RTOX 63 63 A 0,350 3 %
RTOX 80 80 A 0,276 3 %
RTOX 100 100 A 0,221 3 %
RTOX 125 125 A 0,176 3 %
RTOX 160 160 A 0,138 3 %
RTOX 200 200 A 0,110 3 %
RTOX 250 250 A 0,088 3 %
RTOX 315 315 A 0,070 3 %
RTOX 400 400 A 0,055 3 %
RTOX 500 500 A 0,044 3 %
RTOX 630 630 A 0,035 3 %

 

Measurements and weights
Reference In(A) Dimensions mm Weight kg Fig.
A B C D E Ø
RTOX 2,5 2,5 A 150 85 242 57 125 9 2.00 1
RTOX 4 4 A 150 95 242 67 125 9 3.20 1
RTOX 5 5 A 150 95 242 67 125 9 3.30 1
RTOX 6,3 6,3 A 150 95 243 67 125 9 3.40 1
RTOX 8 8 A 150 100 243 72 125 9 4.00 1
RTOX 10 10 A 150 105 244 77 125 9 4.70 1
RTOX 12,5 12,5 A 150 110 244 82 125 9 5.40 1
RTOX 16 16 A 150 115 245 87 125 9 6.30 1
RTOX 20 20 A 150 125 245 97 125 9 7.80 1
RTOX 25 25 A 150 130 245 102 125 9 8.50 1
RTOX 31,5 31,5 A 180 125 281 97 150 9 11.10 1
RTOX 40 40 A 180 140 281 112 150 9 13.90 1
RTOX 50 50 A 180 155 281 127 150 9 16.70 1
RTOX 63 63 A 180 180 281 152 150 9 21.30 1
RTOX 80 80 A 240 196 288 168 200 9 27.30 1
RTOX 100 100 A 240 211 288 183 200 9 32.40 1
RTOX 125 125 A 240 236 288 208 200 9 40.70 1
RTOX 160 160 A 300 192 395 164 250 11 38.70 2
RTOX 200 200 A 300 212 395 184 250 11 49.10 2
RTOX 250 250 A 300 232 395 204 250 11 59.00 2
RTOX 315 315 A 300 267 395 239 250 11 77.00 2
RTOX 400 400 A 300 292 396 264 250 11 93.00 2
RTOX 500 500 A 360 304 467 276 300 11 128.00 2
RTOX 630 630 A 360 344 467 316 300 11 159.00 2

Technical Characteristics
Isolation  Class F - 155ºC
Test voltage  3 kV (1 min, 50 Hz)
Protection degree  IP-00
Includes  Thermal protection against over temperature
Ambient temperature  40ºC
Temperature rise  < 90 ºC
Thermal overload factor  5 %
Line voltage  400 V
Attenuation of voltage spikes at the output of the power converter; these spikes cause deterioration of the motor isolation.
Reduction of the reflection effect due to long cable lengths between converter and motor. This reflection amplifies the voltage at the motor terminals.

These inductors are recommended for cable lengths of 50m or more between power converter and motor.

Inductors and Harmonic filters  

 
RTFX - three phase inductor for capacitor banks  
RTLX - three phase line inductor
RTL - three phase Cast Resin line inductor
RTOX - three phase inductor for output power converter
FTOX - output filter for power converters
PR - single phase line inductor
R - single phase Cast Resin line inductor 
CD - harmonic filter Compensator for office buildings C10D and C20D 
CD - harmonic filter Compensator for office buildings C10D and C22D
CD - harmonic filter Compensator for office buildings C25D-0 and C25D-180, with galvanic isolation
CD - harmonic filter Compensator for office buildings C30D, with galvanic isolation
CF - harmonic filter Compensator for industrial instalations C10F
CF - harmonic filter Compensator for industrial instalations C20F, with galvanic isolation

 

Transformers
DC power supply
Voltage stabilizers

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

   

Home

Products and Services  Corporate Structure  Technologies Site Map Contact us

                      COMLEC PTE LTD    The SkyTech. Blk 2 #05-11 Bukit Batok Street 24. Singapore 659480  Tel:65-67415738  Fax:65-67444696  

                                                                       Email: comlec@pacific.net.sg  or  sales@comlec.com

                        ©copyright 2001~2009 Comlec Pte Ltd. All rights reserved. Disclaimer                        updated 25 Apr 2010