Line inductor for Harmonic
Filtering
| Products in this
family |
| Reference |
In(A) |
Motor
rating |
L(mH) |
| RTL
2,5 |
2,5
A |
0,75
kW / 1 CV |
11,762 |
| RTL
4 |
4 A |
1,1
kW / 1,5 CV |
7,351 |
| RTL
5 |
5 A |
1,5
kW / 2 CV |
5,881 |
| RTL
6,3 |
6,3
A |
2,2
kW / 3 CV |
4,667 |
| RTL
8 |
8 A |
3 kW
/ 4 CV |
3,676 |
| RTL
10 |
10 A |
4 kW
/ 5,5 CV |
2,941 |
| RTL
12,5 |
12,5
A |
5,5
kW / 7,5 CV |
2,352 |
| RTL
16 |
16 A |
6,5
kW / 8,7 CV |
1,838 |
| RTL
20 |
20 A |
7,5
kW / 10 CV |
1,470 |
| RTL
25 |
25 A |
11
kW / 15 CV |
1,176 |
| RTL
31,5 |
31,5
A |
15
kW / 20 CV |
0,933 |
| RTL
40 |
40 A |
18,5
kW / 25 CV |
0,735 |
| RTL
50 |
50 A |
22
kW / 30 CV |
0,588 |
| RTL
63 |
63 A |
30
kW / 40 CV |
0,467 |
| RTL
80 |
80 A |
37
kW / 50 CV |
0,368 |
| RTL
100 |
100
A |
45
kW / 60 CV |
0,294 |
| RTL
125 |
125
A |
55
kW / 75 CV |
0,235 |
|
| Measurements
and weights |
|
| Reference |
In(A) |
Dimensions
mm |
Weight
kg |
Fig. |
| A |
B |
C |
D |
E |
Ű |
| RTL
2,5 |
2,5
A |
135 |
145 |
108 |
125 |
102 |
7 |
1.50 |
1 |
| RTL
4 |
4
A |
135 |
145 |
108 |
125 |
102 |
7 |
1.70 |
1 |
| RTL
5 |
5
A |
135 |
145 |
108 |
125 |
102 |
7 |
2.00 |
1 |
| RTL
6,3 |
6,3
A |
135 |
145 |
108 |
125 |
102 |
7 |
2.50 |
1 |
| RTL
8 |
8
A |
135 |
145 |
108 |
125 |
102 |
7 |
2.70 |
1 |
| RTL
10 |
10
A |
170 |
165 |
138 |
145 |
125 |
7 |
3.40 |
1 |
| RTL
12,5 |
12,5
A |
170 |
165 |
138 |
145 |
125 |
7 |
3.90 |
1 |
| RTL
16 |
16
A |
170 |
165 |
138 |
145 |
125 |
7 |
5.30 |
1 |
| RTL
20 |
20
A |
210 |
198 |
185 |
178 |
173 |
7 |
6.00 |
1 |
| RTL
25 |
25
A |
210 |
198 |
185 |
178 |
173 |
7 |
7.50 |
1 |
| RTL
31,5 |
31,5
A |
210 |
198 |
185 |
178 |
173 |
7 |
9.70 |
1 |
| RTL
40 |
40
A |
210 |
198 |
185 |
178 |
173 |
7 |
10.20 |
1 |
| RTL
50 |
50
A |
280 |
190 |
205 |
80 |
250 |
9 |
13.90 |
2 |
| RTL
63 |
63
A |
280 |
190 |
205 |
100 |
250 |
9 |
16.70 |
2 |
| RTL
80 |
80
A |
280 |
190 |
205 |
115 |
250 |
9 |
20.10 |
2 |
| RTL
100 |
100
A |
280 |
220 |
205 |
110 |
250 |
9 |
24.50 |
2 |
| RTL
125 |
125
A |
340 |
220 |
255 |
106 |
310 |
9 |
30.30 |
2 |
| Technical
Characteristics |
| Frequencies |
50-60 Hz |
| Isolation |
Class F - 155șC |
| Winding |
Class HC-200șC |
| Test voltage |
3 kV (1 min, 50 Hz) |
| Protection degree |
IP-20 |
| Standards |
IEC/EN/UNE-EN 60289 CE |
| Includes |
Thermal protection against over
temperature |
| Ambient temperature |
40șC |
| Temperature rise |
< 90 șC |
| Thermal class |
F |
| Thermal overload
factor |
5 % |
| Line voltage |
380 - 460 V |
Voltage
drop: 4%
- Reduction of current harmonics generated by the load,
resulting in reduced energy consumption and power factor
improvement
- Reduction of the crest factor of the current wave,
extending the lifetime of the equipment and avoiding
breakdowns
- Attenuation of microcuts in the supply voltage generated
by power converters, causing malfuntioning of computers,
PLC's and other sensitive equipment
|
|