| Harmonic filter for the filtering of
hamonics 5, 7, 11, 13, 17, 19
| Products in this
family |
| Reference |
Rating |
Input
V. |
Output
V. |
| C20F
10 |
10
kVA |
400
V |
2 x
400 V+N |
| C20F
12,5 |
12,5
kVA |
400
V |
2 x
400 V+N |
| C20F
16 |
16
kVA |
400
V |
2 x
400 V+N |
| C20F
20 |
20
kVA |
400
V |
2 x
400 V+N |
| C20F
25 |
25
kVA |
400
V |
2 x
400 V+N |
| C20F
31,5 |
31,5
kVA |
400
V |
2 x
400 V+N |
| C20F
40 |
40
kVA |
400
V |
2 x
400 V+N |
| C20F
50 |
50
kVA |
400
V |
2 x
400 V+N |
| C20F
63 |
63
kVA |
400
V |
2 x
400 V+N |
| C20F
80 |
80
kVA |
400
V |
2 x
400 V+N |
| C20F
100 |
100
kVA |
400
V |
2 x
400 V+N |
| C20F
125 |
125
kVA |
400
V |
2 x
400 V+N |
| C20F
160 |
160
VA |
400
V |
2 x
400 V+N |
| C20F
200 |
200
kVA |
400
V |
2 x
400 V+N |
| C20F
250 |
250
kVA |
400
V |
2 x
400 V+N |
|
| Measurements and
weights |
|
| Reference |
Rating |
Dimensions
mm |
Weight
kg |
Fig. |
| A |
B |
C |
D |
E |
Ø |
| C20F 10 |
10 kVA |
622 |
442 |
671 |
|
|
|
121.00 |
|
| C20F 12,5 |
12,5 kVA |
622 |
442 |
671 |
|
|
|
141.00 |
|
| C20F 16 |
16 kVA |
622 |
442 |
671 |
|
|
|
151.00 |
|
| C20F 20 |
20 kVA |
707 |
465 |
836 |
|
|
|
187.00 |
|
| C20F 25 |
25 kVA |
707 |
465 |
836 |
|
|
|
216.00 |
|
| C20F 31,5 |
31,5 kVA |
758 |
479 |
966 |
|
|
|
257.00 |
|
| C20F 40 |
40 kVA |
858 |
600 |
1041 |
|
|
|
325.00 |
|
| C20F 50 |
50 kVA |
858 |
600 |
1041 |
|
|
|
387.00 |
|
| C20F 63 |
63 kVA |
958 |
643 |
1248 |
|
|
|
494.00 |
|
| C20F 80 |
80 kVA |
958 |
643 |
1248 |
|
|
|
573.00 |
|
| C20F 100 |
100 kVA |
1088 |
730 |
1351 |
|
|
|
703.00 |
|
| C20F 125 |
125 kVA |
1088 |
730 |
1351 |
|
|
|
841.00 |
|
| C20F 160 |
160 VA |
1208 |
784 |
1491 |
|
|
|
999.00 |
|
| C20F 200 |
200 kVA |
1208 |
784 |
1491 |
|
|
|
1174.00 |
|
| C20F 250 |
250 kVA |
1422 |
867 |
1639 |
|
|
|
1446.00 |
|
| Technical
Characteristics |
| Frequencies |
50-60 Hz |
| Isolation |
Class H - 180ºC |
| Winding |
Class HC-200ºC |
| Test voltage |
3 kV (1 min, 50 Hz) |
| Cover |
In metal enclosure, epoxy polyester
painted |
| Protection degree |
IP-20 |
| Standards |
IEC/EN/UNE-EN 60076 - 60726 CE |
| |
IEC/EN/UNE-EN 61000-3-2 CE |
| |
IEC/EN/UNE-EN 61000-3-4 IEE 519 CE |
| Includes |
Lifting lugs as from 10 kVA |
| |
Wheels as from 20 kVA |
| Cooling |
ANAN |
| Ambient temperature |
30ºC |
| Filtering of
harmonics coming from the load |
5, 7, 17, 19 |
| |
5, 7, 11, 13, 17, 19 in combination
with RTL or RTLX inductors |
| Reduction of phase
current up to |
20 % |
| |
35 % in combination with inductors
RTL or RTLX |
| Reduction of THD-I
and THD-V up to |
60 % |
| |
85 % in combination with inductors
RTL or RTLX |
Input voltage: 400V,
output: 2 x 400V + N
Note: For selection, please consult the application guides
|
|