| Harmonic filter for the filtering of
hamonics 3, 5, 7, 9, 15, 17, 19
| Products in this
family |
| Reference |
Rating |
Input
V. |
Output
V. |
| C30D
10 |
10
kVA |
400
V + N |
2 x
400 V+N |
| C30D
12,5 |
12,5
kVA |
400
V + N |
2 x
400 V+N |
| C30D
16 |
16
kVA |
400
V + N |
2 x
400 V+N |
| C30D
20 |
20
kVA |
400
V + N |
2 x
400 V+N |
| C30D
25 |
25
kVA |
400
V + N |
2 x
400 V+N |
| C30D
31,5 |
31,5
kVA |
400
V + N |
2 x
400 V+N |
| C30D
40 |
40
kVA |
400
V + N |
2 x
400 V+N |
| C30D
50 |
50
kVA |
400
V + N |
2 x
400 V+N |
| C30D
63 |
63
kVA |
400
V + N |
2 x
400 V+N |
| C30D
80 |
80
kVA |
400
V + N |
2 x
400 V+N |
| C30D
100 |
100
kVA |
400
V + N |
2 x
400 V+N |
| C30D
125 |
125
kVA |
400
V + N |
2 x
400 V+N |
| C30D
160 |
160
kVA |
400
V + N |
2 x
400 V+N |
|
| Measurements and
weights |
|
| Reference |
Rating |
Dimensions
mm |
Weight
kg |
Fig. |
| A |
B |
C |
D |
E |
Ø |
| C30D 10 |
10 kVA |
622 |
442 |
619 |
|
|
|
141.00 |
|
| C30D 12,5 |
12,5 kVA |
622 |
442 |
619 |
|
|
|
151.00 |
|
| C30D 16 |
16 kVA |
707 |
465 |
836 |
|
|
|
187.00 |
|
| C30D 20 |
20 kVA |
707 |
465 |
836 |
|
|
|
216.00 |
|
| C30D 25 |
25 kVA |
758 |
479 |
966 |
|
|
|
257.00 |
|
| C30D 31,5 |
31,5 kVA |
858 |
600 |
1041 |
|
|
|
325.00 |
|
| C30D 40 |
40 kVA |
858 |
600 |
1041 |
|
|
|
387.00 |
|
| C30D 50 |
50 kVA |
958 |
643 |
1248 |
|
|
|
494.00 |
|
| C30D 63 |
63 kVA |
958 |
643 |
1248 |
|
|
|
574.00 |
|
| C30D 80 |
80 kVA |
1088 |
730 |
1351 |
|
|
|
703.00 |
|
| C30D 100 |
100 kVA |
1088 |
730 |
1351 |
|
|
|
841.00 |
|
| C30D 125 |
125 kVA |
1208 |
784 |
1491 |
|
|
|
999.00 |
|
| C30D 160 |
160 kVA |
1208 |
784 |
1491 |
|
|
|
1174.00 |
|
| Technical
Characteristics |
| Frequencies |
50-60 Hz |
| Isolation |
Class H - 180ºC |
| Winding |
Class HC-200ºC |
| Test voltage |
3 kV (1 min, 50 Hz) |
| Cover |
In metal enclosure, epoxy polyester
painted |
| Protection degree |
IP-20 |
| Standards |
IEC/EN/UNE-EN 60076 - 60726 CE |
| |
IEC/EN/UNE-EN 61000-3-2 CE |
| |
IEC/EN/UNE-EN 61000-3-4 IEE 519 CE |
| Includes |
Lifting lugs |
| |
Wheels as from 16 kVA |
| Cooling |
ANAN |
| Ambient temperature |
30ºC |
| Maximal admissible
3rd harmonic voltage |
- - |
| Maximum admissible
THD-I |
110 % |
| Filtering of
harmonics coming from the load |
3, 5, 7, 9, 15, 17, 19 |
| Reduction of
neutral current and neutral - earth voltage up to |
90 % |
| Reduction of phase
current up to |
45 % |
| Reduction of THD-I
and THD-V up to |
85 % |
Input voltage: 400V+N,
output: 2 x 400V + N
Note: For selection, please consult the application guides
|
|