| Products in this family |
| Reference |
Rating |
Input V. |
Output
V. |
| FC1 |
1 A |
230 V |
12-24 Vdc |
| FC2.5 |
2,5 A |
230 V |
12-24 Vdc |
| FC5 |
5 A |
230 V |
12-24 Vdc |
| FC10 |
10 A |
230 V |
24 Vdc |
| FCB10 |
10 A |
230 V |
12 Vdc |
|
| Measurements and weights |
| |
| Reference |
Rating |
Dimensions
mm |
Weight kg |
Fig. |
| A |
B |
C |
D |
E |
Ø |
| FC10 |
10 A |
330 |
141 |
152 |
122 |
348 |
6 |
8.10 |
3 |
| FCB10 |
10 A |
330 |
141 |
152 |
122 |
348 |
6 |
6.10 |
3 |
| FC2.5 |
2,5 A |
70 |
141 |
152 |
|
|
6 |
2.30 |
1 |
| FC5 |
5 A |
130 |
141 |
152 |
|
|
6 |
4.10 |
2 |
| FC1 |
1 A |
60 |
141 |
138 |
|
|
6 |
1.50 |
1 |
| Technical Characteristics |
| Frequencies |
50-60 Hz |
| Protection |
Class I |
| Test voltage |
3 kV (1 min, 50 Hz) between input and
output |
| |
3 kV (1 min, 50 Hz) between input and
earth |
| |
0,5 kV (1 min, 50 Hz) between output
and earth |
| Mounting |
DIN Rail (FC 1, FC 2,5, FC 5),
mounting screws (FC 10, FCB 10) |
| Protection degree |
IP-20 |
| Standards |
Functional: IEC/EN/UNE-EN 61204 CE |
| |
Security: IEC/EN/UNE 60950 CE |
| |
CE directives: 73/23 CEE, 93/68 CEE,
86/336 CEE |
| |
Interferences: IEC 61000-3-2/3, IEC
61000-4-2/4/5/8/11, EN 55022 |
| |
Transformer: IEC/EN/UNE_EN 61558 |
| Ambient temperature |
40ºC |
| Output voltage accuracy |
+/-1% |
| Output ripple |
100 mV (p - p) |
| Output voltage
adjustment |
10,8-26,4 VDC (FC 1, FC 2,5, FC 5),
21,6-26,4 VDC (FC 10), 10,8-13,2 VDC (FCB10) |
| Output protection |
Galvanic isolation by ultra-isolating
transformer with electrostatic screen |
| |
Short-circuit and overload (constant
current type) |
| Input voltage margin |
Output adjusted to 24VDC: -15,+10%
(FC 1), -15,+15% (FC 2,5, FC 5, FC 10) |
| |
Output adjusted to 12VDC: -20,+15%
(FC 1), -30,+15% (FC 2,5, FC 5, FCB 10) |
| Efficiency |
FC 1: 64%, FC 2,5: 66%, FC 5: 68%, FC
10: 70%, FCB 10: 70% |
Option: Bracket for back
panel mounting (FC1, FC2,5, FC5) Ref.: SFC, Price: 6,61 Euro
- Output voltage adjustable from 10,8VDC to 26,4VDC (FC1,
FC2,5, FC5)
- According to standards for the immunity and emission of
harmonics and perturbations
- Totally protected against perturbations from the supply
network or load by means of an ultra isolated transformer with
screen, varistors, supressor diode and EMI filter.
|